Quels sont les degrés de précision des plates-formes à coussin d'air ?

The precision grades of precision air-bearing platforms (granite air-bearing platforms) are generally classified in the industry into two systems: motion accuracy and planar referen

I. Granite Platform Precision Grade (Metrology Grade)
This is the base grade, determining how accurate the reference surface is:Table
Grade Flatness (Typical) Applicable Equipment
Grade 000 ≤ 2 μm/m² Ultra-high precision CMM, semiconductor inspection, lit air-bearing platforms
Grade 00 ≤ 3 μm/m² High precision CMM, precision air-bearing motion platforms, inspection tables
Grade 0 ≤ 5 μm/m² General measuring machines, precision workbenches
Grade 1 ≤ 10 μm/m² Inspection platforms, marking platforms
Air-bearing plat exclusively use: Grade 00, Grade 000

II. Air-bearing Motion Platform Precision Grade (Industry Standard)
Divided into 4 levels based on positioning acy and repeatability, directly corresponding to equipment tiers:

  1. General Precision Level
    Repeatability: ±1 μm
    Positioning AccuraApplications: General inspection, semi-automatic alignment
  2. High Precision Level (Most Common)
    Repeatability: ±0.5 μm
    Positioning Acuracy: ±1~2 μm
    Applications: Standard granite air-bearing platforms, high-end CMM, optical inspection
  3. Ultra-high Precision Level
    Repeatablity: ±0.1~0.2 μm
    Positioning Accuracy: ±0.5 μm
    Applications: Semiconductor front-end inspection, laser interferometry, nano-alignment
    4.ano Level
    Repeatability: ±10~50 nm
    Positioning Accuracy: Within ±0.1 μm
    Applications: Lithography, quantum precision, nimprint

III. Air-bearing Platform Straightness and Perpendicularity Grades (Intuitive Judgment)
High-end air-bearing platform straightness: .1~0.5 μm/300mm
Perpendicularity: ±1~3 μm/m
Motion Smoothness: No crawling, no vibration, no jitter

IV. Simplest Memorizat Method (Use directly for Quotation / Selection)
Grade 000 Granite Repeatability ±0.1~0.5 μm = Ultra-high Precision Air-beariatform
Grade 00 Granite Repeatability ±0.5~1 μm = High Precision Air-bearing Platform
Below this, it is generally not considered a precisioning platform.