{"id":1956,"date":"2026-03-02T08:51:37","date_gmt":"2026-03-02T00:51:37","guid":{"rendered":"https:\/\/jtlcnc.com\/?p=1956"},"modified":"2026-03-02T08:51:47","modified_gmt":"2026-03-02T00:51:47","slug":"how-to-check-the-straightness-of-granite-straightedge","status":"publish","type":"post","link":"https:\/\/jtlcnc.com\/fr\/2026\/03\/02\/how-to-check-the-straightness-of-granite-straightedge\/","title":{"rendered":"Comment v\u00e9rifier la rectitude d'une r\u00e8gle en granit ?"},"content":{"rendered":"<p>Method 1: Pitch Method (High Precision, for Arbitration \/ Acceptance)<br>Appl Scenarios: Factory Inspection, Customer Acceptance, High-Precision Tooling Calibration.<br>Required Tools: Digital Level (or Repeating Level), Plate (Pitch Block), Recording Form.<br>\u3010Direct Execution Steps\u3011<br>Preparation: Place the granite straight edge stably on the temperature-controlled workbench20\u2103\u00b12\u2103), preheat for 1 hour to be isothermal.<br>Segmentation: Use the bridge plate to divide the measuring surface of the straight edge n equal parts (e.g., divide a 1000mm straight edge into 10 parts, each part is 100mm).<br>Measure: Start from one end, move the bridge plate to each segment in turn, and record the readings (grid values) of the level.<br>Recording: Fill the readings into table and calculate the cumulative values.<br>Assessment: Draw the error curve according to the cumulative values, and the difference between the highest and lowest points of the vertical coordinate of curve is the straightness error.<br>Method 2: Polishing Transparency Method (Workshop Level, Quick Self-Inspection)<br>Applicable Scenarios: Precheck before daily use, Wear Check, No need for specific values.<br>Required Tools: Grade 0 Flat Crystal (or more precise granite flat ruler), Mineral Oil ( engine oil).<br>\u3010Direct Execution Steps\u3011<br>Cleaning: Thoroughly wipe the measuring surface of the straight edge and the surface of the flat crystal with anhyd ethanol to ensure no dust.<br>Oil Application: Apply a very thin layer of red oil (indicator) evenly on the flat crystal.<br>Polishing: Gently place flat crystal on the measuring surface of the straight edge, gently reciprocate and move back and forth (the distance is about 1\/3 of the length of the flat crystal.<br>Observation: Take off the flat crystal, observe the coloring situation on the surface of the straight edge:<br>Qualified: Uniform coloring, no interruption, or interference fringes appear (uniform transparency).<br>Unqualified: No color in some places (protuberance), or local stripes are seriously bent, and obvious dark areas.<br>Method 3: Dial Method (Visual Method, Suitable for Long Rulers)<br>Applicable Scenarios: No level on site, need to see specific jump value.<br>Required Tools: Marble Platform (Reference Surface), Dial Indicator (Lever Dial), Indicator Base.<br>\u3010Direct Execution\u3011<br>Setup: Place the granite straight edge on the marble platform, fix the dial indicator on the indicator base, and press the measuring tip vertically on the measuring surface of the straight.<br>Movement: Let the dial indicator move slowly and uniformly along the full length of the straight edge (or move the straight edge).<br>Reading: Record the maximum and the minimum reading of the dial indicator during the movement.<br>Calculation: Maximum value &#8211; Minimum value = Straightness Error (Note: This method is affected by the accuracy of the platform, for reference only).<br>Key Points for Attention (Avoid Pit Guide)<br>Isothermal Treatment: Granite has slow heat conduction, it must be placed in the workshop for more than 1 hour after picking up from the warehouse, otherwise, thermal deformation will cause all the data to be wrong.<br>Uniform Force: When placing, be, prohibit single-point support or compression of both ends during handling, and prevent elastic deformation.<br>Temperature Control: Prohibit direct blowing of the air conditioner during detection, and personnel from breathing directly to the measuring surface (the water vapor exhaled will change the local temperature).<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img alt=\"\" fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/jtlcnc.com\/wp-content\/uploads\/2026\/01\/zhijiaochi-1024x768.jpg\" class=\"wp-image-1449\" srcset=\"https:\/\/jtlcnc.com\/wp-content\/uploads\/2026\/01\/zhijiaochi-1024x768.jpg 1024w, https:\/\/jtlcnc.com\/wp-content\/uploads\/2026\/01\/zhijiaochi-300x225.jpg 300w, https:\/\/jtlcnc.com\/wp-content\/uploads\/2026\/01\/zhijiaochi-768x576.jpg 768w, https:\/\/jtlcnc.com\/wp-content\/uploads\/2026\/01\/zhijiaochi-16x12.jpg 16w, https:\/\/jtlcnc.com\/wp-content\/uploads\/2026\/01\/zhijiaochi-800x600.jpg 800w, https:\/\/jtlcnc.com\/wp-content\/uploads\/2026\/01\/zhijiaochi.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>","protected":false},"excerpt":{"rendered":"<p>Method 1: Pitch Method (High Precision, for Arbitration \/ Acceptance)Appl Scenarios: Factory Inspection, Customer Acceptance, High-Precision Tooling Calibration.Required Tools: Digital Level (or Repeating Level), Plate (Pitch Block), Recording Form.\u3010Direct Execution Steps\u3011Preparation: Place the granite straight edge stably on the temperature-controlled workbench20\u2103\u00b12\u2103), preheat for 1 hour to be isothermal.Segmentation: Use the bridge plate to divide the&#8230;<\/p>","protected":false},"author":1,"featured_media":1287,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_seopress_robots_primary_cat":"none","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":"","_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","footnotes":""},"categories":[35],"tags":[],"class_list":["post-1956","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"taxonomy_info":{"category":[{"value":35,"label":"NEWS"}]},"featured_image_src_large":["https:\/\/jtlcnc.com\/wp-content\/uploads\/2026\/01\/\u76f4\u89d2\u5c3a4-11.webp",220,220,false],"author_info":{"display_name":"jinxing6611@gmail.com","author_link":"https:\/\/jtlcnc.com\/fr\/author\/jtlcnc\/"},"comment_info":0,"category_info":[{"term_id":35,"name":"NEWS","slug":"news","term_group":0,"term_taxonomy_id":35,"taxonomy":"category","description":"","parent":0,"count":121,"filter":"raw","cat_ID":35,"category_count":121,"category_description":"","cat_name":"NEWS","category_nicename":"news","category_parent":0}],"tag_info":false,"_links":{"self":[{"href":"https:\/\/jtlcnc.com\/fr\/wp-json\/wp\/v2\/posts\/1956","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/jtlcnc.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/jtlcnc.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/jtlcnc.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/jtlcnc.com\/fr\/wp-json\/wp\/v2\/comments?post=1956"}],"version-history":[{"count":1,"href":"https:\/\/jtlcnc.com\/fr\/wp-json\/wp\/v2\/posts\/1956\/revisions"}],"predecessor-version":[{"id":1959,"href":"https:\/\/jtlcnc.com\/fr\/wp-json\/wp\/v2\/posts\/1956\/revisions\/1959"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/jtlcnc.com\/fr\/wp-json\/wp\/v2\/media\/1287"}],"wp:attachment":[{"href":"https:\/\/jtlcnc.com\/fr\/wp-json\/wp\/v2\/media?parent=1956"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/jtlcnc.com\/fr\/wp-json\/wp\/v2\/categories?post=1956"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/jtlcnc.com\/fr\/wp-json\/wp\/v2\/tags?post=1956"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}