{"id":2790,"date":"2026-05-22T08:37:16","date_gmt":"2026-05-22T00:37:16","guid":{"rendered":"https:\/\/jtlcnc.com\/?p=2790"},"modified":"2026-05-22T08:37:17","modified_gmt":"2026-05-22T00:37:17","slug":"how-are-the-accuracy-grades-of-granite-precision-gauges-classified","status":"publish","type":"post","link":"https:\/\/jtlcnc.com\/es\/2026\/05\/22\/how-are-the-accuracy-grades-of-granite-precision-gauges-classified\/","title":{"rendered":"\u00bfC\u00f3mo se clasifican los grados de precisi\u00f3n de los calibres de precisi\u00f3n de granito?"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Accuracy Grade Classification of Granite Precision Gauges (Surface Plates \/ Platforms)<br>Domestically, the mainstream standard is GB\/T 20428-2021 &#8220;Rock Surface Plates&#8221;, while internationally, ISO 8512-2 and DIN 876 are commonly used. The core classification is based on flatness tolerance, distinguishing grades 000, 00, 0, 1, and 2, with accuracy decreasing from high to low.<br>I. National Standard GB\/T 20428-2021 Grades (Most Commonly Used)<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Accuracy Grades (from high to low)<br>Grade 000 \u2192 Grade 00 \u2192 Grade 0 \u2192 Grade 1 \u2192 Grade 2<br>Grade 000, Grade 00: Ultra-precision grade, used for CMM bases, laboratory references, and metrology room standard surface plates<br>Grade 0: Precision inspection, laboratories, and high-precision machine tool accessories<br>Grade 1: Workshop precision inspection, scribing, and tooling verification<br>Grade 2: Ordinary workshop scribing, assembly, and fitter platforms<\/li>\n\n\n\n<li>Core Rules for Flatness Tolerance (Unit: \u03bcm, taking 600\u00d7400mm as an example)<br>Grade 000: Flatness \u2248 1.47\u03bcm<br>Grade 00: \u2248 2.94\u03bcm<br>Grade 0: \u2248 5.88\u03bcm<br>Grade 1: \u2248 11.76\u03bcm<br>Grade 2: \u2248 23.52\u03bcm<br>Formula: Flatness Tolerance = Coefficient \u00d7 \u221a(Length \u00d7 Width)<br>Coefficients: 000=0.003; 00=0.006; 0=0.012; 1=0.024; 2=0.048<br>II. International Standard Comparison<br>ISO 8512-2: Corresponds to grades 00, 0, 1, and 2, basically consistent with the national standard<br>German DIN 876:<br>Grade 00 (Ultra-precision), Grade 0 (Precision), Grade 1 (Normal)<br>US ASME B89.3.7: Grades AA, A, B, and C, where AA \u2248 Grade 000, A \u2248 Grade 00<br>III. Reference for Selecting Granite Gauge Grades<br>Grade 000 \/ 00: CMMs, vision system bases, metrology institute standards, ultra-precision laboratories<br>Grade 0: Precision machining workshop inspection, gauge verification, high-precision tooling<br>Grade 1: Regular precision inspection, scribing, mold inspection<br>Grade 2: Ordinary assembly, fitting, welding tooling<br>IV. Key Supplements<br>The larger the accuracy grade number, the larger the tolerance and the lower the accuracy; Grade 000 is the highest, and Grade 2 is the lowest.<br>Granite materials such as Jinan Green, Zhangqiu Black, and Indian stone are preferred. Only materials with uniform density and good thermal stability can stably achieve Grade 000\/00.<br>In addition to flatness, high-precision gauges will also specify: parallelism, perpendicularity, surface roughness, and linear expansion coefficient.<\/li>\n<\/ol>\n\n\n\n<figure class=\"wp-block-image size-full\"><img alt=\"\" fetchpriority=\"high\" decoding=\"async\" width=\"1008\" height=\"718\" src=\"https:\/\/jtlcnc.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260521091502_4_11.png\" class=\"wp-image-2791\" srcset=\"https:\/\/jtlcnc.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260521091502_4_11.png 1008w, https:\/\/jtlcnc.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260521091502_4_11-300x214.png 300w, https:\/\/jtlcnc.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260521091502_4_11-768x547.png 768w, https:\/\/jtlcnc.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260521091502_4_11-18x12.png 18w, https:\/\/jtlcnc.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260521091502_4_11-800x570.png 800w\" sizes=\"(max-width: 1008px) 100vw, 1008px\" \/><\/figure>","protected":false},"excerpt":{"rendered":"<p>Clasificaci\u00f3n por grados de precisi\u00f3n de los calibres de precisi\u00f3n de granito (placas de superficie \/ plataformas). A nivel nacional, la norma m\u00e1s utilizada es la GB\/T 20428-2021 \u201cPlacas de superficie de roca\u201d, mientras que a nivel internacional se suelen emplear las normas ISO 8512-2 y DIN 876. La clasificaci\u00f3n principal se basa en la tolerancia de planitud y distingue los grados 000, 00, 0, 1 y 2, con una precisi\u00f3n que disminuye de mayor a menor. I. Norma nacional\u2026<\/p>","protected":false},"author":1,"featured_media":2791,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"","_seopress_redirections_param":"","_seopress_redirections_type":0,"_seopress_analysis_target_kw":"","_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","footnotes":""},"categories":[35],"tags":[],"class_list":["post-2790","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"taxonomy_info":{"category":[{"value":35,"label":"NEWS"}]},"featured_image_src_large":["https:\/\/jtlcnc.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260521091502_4_11.png",1008,718,false],"author_info":{"display_name":"jinxing6611@gmail.com","author_link":"https:\/\/jtlcnc.com\/es\/author\/jtlcnc\/"},"comment_info":0,"category_info":[{"term_id":35,"name":"NEWS","slug":"news","term_group":0,"term_taxonomy_id":35,"taxonomy":"category","description":"","parent":0,"count":311,"filter":"raw","cat_ID":35,"category_count":311,"category_description":"","cat_name":"NEWS","category_nicename":"news","category_parent":0}],"tag_info":false,"_links":{"self":[{"href":"https:\/\/jtlcnc.com\/es\/wp-json\/wp\/v2\/posts\/2790","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/jtlcnc.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/jtlcnc.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/jtlcnc.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/jtlcnc.com\/es\/wp-json\/wp\/v2\/comments?post=2790"}],"version-history":[{"count":1,"href":"https:\/\/jtlcnc.com\/es\/wp-json\/wp\/v2\/posts\/2790\/revisions"}],"predecessor-version":[{"id":2792,"href":"https:\/\/jtlcnc.com\/es\/wp-json\/wp\/v2\/posts\/2790\/revisions\/2792"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/jtlcnc.com\/es\/wp-json\/wp\/v2\/media\/2791"}],"wp:attachment":[{"href":"https:\/\/jtlcnc.com\/es\/wp-json\/wp\/v2\/media?parent=2790"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/jtlcnc.com\/es\/wp-json\/wp\/v2\/categories?post=2790"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/jtlcnc.com\/es\/wp-json\/wp\/v2\/tags?post=2790"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}