{"id":2497,"date":"2026-04-24T08:00:21","date_gmt":"2026-04-24T00:00:21","guid":{"rendered":"https:\/\/jtlcnc.com\/?p=2497"},"modified":"2026-04-24T08:00:24","modified_gmt":"2026-04-24T00:00:24","slug":"how-to-choose-a-suitable-laser-interferometer-to-inspect-the-accuracy-of-a-granite-platform","status":"publish","type":"post","link":"https:\/\/jtlcnc.com\/ar\/2026\/04\/24\/how-to-choose-a-suitable-laser-interferometer-to-inspect-the-accuracy-of-a-granite-platform\/","title":{"rendered":"How to choose a suitable laser interferometer to inspect the accuracy of a granite platform?"},"content":{"rendered":"<p>Laser Interferometer Dedicated for Granite Platforms | Comprehensive Selection Guide (Universal fo Grade 000\/00\/0)<br>Select based on 5 core dimensions: platform accuracy grade, table size, workshop environment, inspection items, and national standard traceability. Directly matches ite flatness \/ straightness \/ perpendicularity 3D inspection.<\/p>\n\n\n\n<p>I. Determine the Core First: Single-Frequency vs. Dual-Frequency Laser (Must Choose Dual-Fy)<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Single-Frequency Laser Interferometer<br>Accuracy: \u00b11ppm, Resolution 0.01\u03bcm<br>Poor anti-interference: Drifts due to tempere drift, air currents, and slight vibrations<br>Only suitable for: Constant temperature dust-free laboratories, small tables Grade 0 and below, static calibration<br>\u274c Not recommended for on-site workshop met of granite platforms<\/li>\n\n\n\n<li>Dual-Frequency Laser Interferometer (Standard for granite inspection \u00b7 Similar to Renishaw XL-80)<br>Accura, Resolution 0.6nm<br>Extremely strong heterodyne anti-interference, no drift from air conditioning, workshop vibrations, or temperature fluctuations<br>No cumulative error over lones, suitable for large granite bases \/ gantry tables<br>\u2705 The only first choice for factory calibration of Grade 000\/00 platforms and CMA metrology arbi<\/li>\n<\/ol>\n\n\n\n<p>II. Select Instrument Grade Based on Granite Platform Accuracy Grade<br>\u0627\u0644\u062c\u062f\u0648\u0644<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Granite Platform Grade<\/th><th>Flatness Requirement<\/th><th>Minimum Laser Interferometer Configuration<\/th><\/tr><\/thead><tbody><tr><td>Grade 000 (Semiconductor \/ CMM Reference)<\/td><td>\u22642\u03bcm\/m<\/td><td>Nanometer-level dual-frequency angular flatness accessory full grid 3D fiting<\/td><\/tr><tr><td>Grade 00 (Optical \/ Ultra-high Precision Fixtures)<\/td><td>\u22645\u03bcm\/m<\/td><td>High-precision dual-frequency, angular interferometer module<\/td><\/tr><tr><td>Grade 0 (Workshop Precisio Inspection)<\/td><td>\u226410\u03bcm\/m<\/td><td>Standard dual-frequency straightness angle combination<\/td><\/tr><tr><td>Grade 1 and below<\/td><td>\u226515\u03bcm\/m<\/td><td>Electronic level isfficient, no laser needed<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>III. Select Measurement Range &amp; Bridge Configuration Based on Table Size<br>\u22641500mm Small Platforms<br>Range: 0~4m is suffiient<br>Bridge: Standard 150\/200mm pitch<br>1500~3000mm Medium Platforms \/ Machine Tool Beds<br>, prioritize angular interferometry method, no cumulative error over long distances<br>Extended bridge long-distance retroreflector assembly<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>3000mm Large Gantry \/ Granite Beams<br>Range: 0~15m , Angular laser interferometry<br>Pair with laser tracker to verify overall plane cloud map<\/p>\n<\/blockquote>\n\n\n\n<p>IV. Must Equip with Granite-Specific Inspection Aessories (No exceptions allowed)<br>Angular Interferometer Set (Core for flatness)<br>Measures table tilt and undulation \u2192 converts to full plane height difference, dedicated for national sandard JJG117 plate calibration<br>Flatness Scanning Bridge Granite-Specific Retroreflector<br>Conforms to stone mirror surface, does not scratch working surface, moves smoothly without vibrationTemperature, Humidity, and Air Pressure Compensation Module<br>Granite is sensitive to thermal expansion, automatically corrects temperature \/ air pressure \/ air refractive index errors<br>OrthogonalAngle Mirror Set: Simultaneously measures perpendicularity, parallelism, and position<br>Grid Flatness Software: Cross diagonal full-area sampling, least squares evaluation, outp error cloud map<\/p>\n\n\n\n<p>V. Workshop Environment Adaptation Selection (Key to stable readings on-site)<br>Constant Temperature Dust-Free Workshop (20\u00b10.5\u2103): Any dual-freques acceptable<br>Ordinary Production Workshop (with vibration, direct AC airflow)<br>Must select: High-stability dual-frequency strong environmental compensation wireless acquisition, isolates air current and vibration nterference<br>Humid and Dusty Environment: Select sealed optical mirror set, oil-proof coating, protects laser beam path<\/p>\n\n\n\n<p>VI. Key Technical Parameter Hard Thresholds (Must be met for Grade 00 Granite or above)<br>Laser frequency stabilization accracy: \u2264\u00b10.05ppm<br>Angular resolution: \u22640.001\u2033 (arcseconds), corresponding height difference 0.001\u03bcm\/m<br>Repetability: \u22640.1\u03bcm, no deviation in multiple re-measurements<br>Complies with JJG117 and GB\/T4987 granite surface plate verification regulati; capable of issuing CNAS\/CMA calibration certificates<br>Helium-neon stabilized light source, wavelength 632.8nm, long-term stability, no attenuation ovr time<\/p>\n\n\n\n<p>VII. Mainstream Model Selection (Industry Standard)<br>Imported High-End (Grade 000 Arbitration \/ CMM Acceptance): Renisha80<br>Full form and position measurement, top-tier anti-interference, software adapted to national standards, traceable to national benchmarks<br>Domestic High Precision (Factory mass production verification cost-effectival-frequency laser full set of planar angle modules<br>Meets accuracy standards, fast after-sales service, moderate price, suitable for batch inspection of Grade 00\/0 granie platforms<br>Not Recommended: Low-end single-frequency, short range, no angle module, no dedicated flatness algorithm<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img alt=\"\" fetchpriority=\"high\" decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/jtlcnc.com\/wp-content\/uploads\/2026\/02\/\u5fae\u4fe1\u56fe\u7247_20230325152820-768x1024.jpg\" class=\"wp-image-1747\" srcset=\"https:\/\/jtlcnc.com\/wp-content\/uploads\/2026\/02\/\u5fae\u4fe1\u56fe\u7247_20230325152820-768x1024.jpg 768w, https:\/\/jtlcnc.com\/wp-content\/uploads\/2026\/02\/\u5fae\u4fe1\u56fe\u7247_20230325152820-225x300.jpg 225w, https:\/\/jtlcnc.com\/wp-content\/uploads\/2026\/02\/\u5fae\u4fe1\u56fe\u7247_20230325152820-1152x1536.jpg 1152w, https:\/\/jtlcnc.com\/wp-content\/uploads\/2026\/02\/\u5fae\u4fe1\u56fe\u7247_20230325152820-9x12.jpg 9w, https:\/\/jtlcnc.com\/wp-content\/uploads\/2026\/02\/\u5fae\u4fe1\u56fe\u7247_20230325152820-800x1066.jpg 800w, https:\/\/jtlcnc.com\/wp-content\/uploads\/2026\/02\/\u5fae\u4fe1\u56fe\u7247_20230325152820.jpg 1280w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/><\/figure>","protected":false},"excerpt":{"rendered":"<p>Laser Interferometer Dedicated for Granite Platforms | Comprehensive Selection Guide (Universal fo Grade 000\/00\/0)Select based on 5 core dimensions: platform accuracy grade, table size, workshop environment, inspection items, and national standard traceability. Directly matches ite flatness \/ straightness \/ perpendicularity 3D inspection. I. Determine the Core First: Single-Frequency vs. Dual-Frequency Laser (Must Choose Dual-Fy) II&#8230;.<\/p>","protected":false},"author":1,"featured_media":2500,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_seopress_robots_primary_cat":"none","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":"","_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","footnotes":""},"categories":[35],"tags":[],"class_list":["post-2497","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"taxonomy_info":{"category":[{"value":35,"label":"NEWS"}]},"featured_image_src_large":["https:\/\/jtlcnc.com\/wp-content\/uploads\/2026\/04\/\u5fae\u4fe1\u56fe\u7247_20260420143653_86_25.png",709,888,false],"author_info":{"display_name":"jinxing6611@gmail.com","author_link":"https:\/\/jtlcnc.com\/ar\/author\/jtlcnc\/"},"comment_info":0,"category_info":[{"term_id":35,"name":"NEWS","slug":"news","term_group":0,"term_taxonomy_id":35,"taxonomy":"category","description":"","parent":0,"count":155,"filter":"raw","cat_ID":35,"category_count":155,"category_description":"","cat_name":"NEWS","category_nicename":"news","category_parent":0}],"tag_info":false,"_links":{"self":[{"href":"https:\/\/jtlcnc.com\/ar\/wp-json\/wp\/v2\/posts\/2497","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/jtlcnc.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/jtlcnc.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/jtlcnc.com\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/jtlcnc.com\/ar\/wp-json\/wp\/v2\/comments?post=2497"}],"version-history":[{"count":1,"href":"https:\/\/jtlcnc.com\/ar\/wp-json\/wp\/v2\/posts\/2497\/revisions"}],"predecessor-version":[{"id":2501,"href":"https:\/\/jtlcnc.com\/ar\/wp-json\/wp\/v2\/posts\/2497\/revisions\/2501"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/jtlcnc.com\/ar\/wp-json\/wp\/v2\/media\/2500"}],"wp:attachment":[{"href":"https:\/\/jtlcnc.com\/ar\/wp-json\/wp\/v2\/media?parent=2497"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/jtlcnc.com\/ar\/wp-json\/wp\/v2\/categories?post=2497"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/jtlcnc.com\/ar\/wp-json\/wp\/v2\/tags?post=2497"}],"curies":[{"name":"\u062f\u0628\u0644\u064a\u0648 \u0628\u064a","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}